Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1997 1
1998 2
1999 1
2002 1
2004 2
2021 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

8 results

Results by year

Filters applied: . Clear all
Page 1
Determination of Intestinal Viral Loads and Distribution of Bovine Viral Diarrhea Virus, Classical Swine Fever Virus, and Peste Des Petits Ruminants Virus: A Pilot Study.
Jelsma T, Wijnker JJ, Smid B, Verheij E, van der Poel WHM, Wisselink HJ. Jelsma T, et al. Pathogens. 2021 Sep 14;10(9):1188. doi: 10.3390/pathogens10091188. Pathogens. 2021. PMID: 34578220 Free PMC article.
The aim of this pilot study was to determine viral loads and distribution over the total length, at short distances, and in the separate layers of the intestine of virus-infected animals for future inactivation studies. Two calves, two pigs, and two goats were infected wit …
The aim of this pilot study was to determine viral loads and distribution over the total length, at short distances, and in the separate lay …
At least thirty-four days of animal continuous perfusion by a newly developed extracorporeal membrane oxygenation system without systemic anticoagulants.
Nishinaka T, Tatsumi E, Taenaka Y, Katagiri N, Ohnishi H, Shioya K, Fukuda T, Oshikawa M, Sato K, Tsukiya T, Homma A, Takewa Y, Takano H, Sato M, Kashiwabara S, Tanaka H, Sakai K, Matsuda T. Nishinaka T, et al. Artif Organs. 2002 Jun;26(6):548-51. doi: 10.1046/j.1525-1594.2002.06886_3.x. Artif Organs. 2002. PMID: 12072113
The entire blood-contacting surface of the system is coated with a newly developed heparin material (Toyobo-NCVC coating). We performed a venoarterial bypass in a goat, and the ECMO system was driven for 34 days without systemic anticoagulants. ...Thrombus formation was ha …
The entire blood-contacting surface of the system is coated with a newly developed heparin material (Toyobo-NCVC coating). We performed a ve …
Development of an implantable centrifugal blood pump for circulatory assist.
Wakisaka Y, Taenaka Y, Chikanari K, Okuzono Y, Endo S, Takano H. Wakisaka Y, et al. ASAIO J. 1997 Sep-Oct;43(5):M608-14. ASAIO J. 1997. PMID: 9360117
Waterproofing and histocompatibility were supported by a silicone seal and a casing made of titanium and acrylic resin. Overall efficiency was 30% and normalized index of homolysis was 0.003 mg/dl, the same value as the BP-80, at a flow rate of 5 L/min and a head of 100 mm …
Waterproofing and histocompatibility were supported by a silicone seal and a casing made of titanium and acrylic resin. Overall effic …
Intrathoracic and intraabdominal wall implantation of a centrifugal blood pump for circulatory assist.
Wakisaka Y, Taenaka Y, Chikanari K, Okuzono Y, Nishimura T, Endo S, Nakatani T, Takano H. Wakisaka Y, et al. Artif Organs. 1998 Jun;22(6):493-7. doi: 10.1046/j.1525-1594.1998.06133.x. Artif Organs. 1998. PMID: 9650671
The watertightness and histocompatibility of the ICP are supported by its silicone ring seal and its casing of titanium and acrylic resin, respectively. The total efficiency of the ICP was 30% at a 5 L/min flow rate and a 100 mm Hg head. The heat generation, watertightness …
The watertightness and histocompatibility of the ICP are supported by its silicone ring seal and its casing of titanium and acrylic r …
Development of design methods of a centrifugal blood pump with in vitro tests, flow visualization, and computational fluid dynamics: results in hemolysis tests.
Takiura K, Masuzawa T, Endo S, Wakisaka Y, Tatsumi E, Taenaka Y, Takano H, Yamane T, Nishida M, Asztalos B, Konishi Y, Miyazoe Y, Ito K. Takiura K, et al. Artif Organs. 1998 May;22(5):393-8. doi: 10.1046/j.1525-1594.1998.06149.x. Artif Organs. 1998. PMID: 9609347
The commercially available Nikkiso centrifugal blood pump (HPM-15) was used as a standard, and the dimensions of 2 types of gaps between the impeller and the casing, the axial and the radial gap, were varied. Four impellers with different vane outlet angles were also prepa …
The commercially available Nikkiso centrifugal blood pump (HPM-15) was used as a standard, and the dimensions of 2 types of gaps between the …
Comparative histological studies of mechanically versus manually processed sheep intestines used to make natural sausage casings.
Koolmees PA, Tersteeg MH, Keizer G, van den Broek J, Bradley R. Koolmees PA, et al. J Food Prot. 2004 Dec;67(12):2747-55. doi: 10.4315/0362-028x-67.12.2747. J Food Prot. 2004. PMID: 15633681 Free article.
The natural sausage casings industry is large and worldwide, and casings prepared from the small intestine of sheep form a large part of it. ...No serosa was found in any casing, but some residual mucosa and muscularis was retained, with more of the former th …
The natural sausage casings industry is large and worldwide, and casings prepared from the small intestine of sheep form a lar …
Development of design methods for a centrifugal blood pump with a fluid dynamic approach: results in hemolysis tests.
Masuzawa T, Tsukiya T, Endo S, Tatsumi E, Taenaka Y, Takano H, Yamane T, Nishida M, Asztalos B, Miyazoe Y, Ito K, Sawairi T, Konishi Y. Masuzawa T, et al. Artif Organs. 1999 Aug;23(8):757-61. doi: 10.1046/j.1525-1594.1999.06417.x. Artif Organs. 1999. PMID: 10463503
The studied parameters were the radial gap between the outer edge of the impeller vane and the casing wall, the position of the outlet port, and the discharge angle of the impeller vane. ...
The studied parameters were the radial gap between the outer edge of the impeller vane and the casing wall, the position of the outle …
Development of an electro-stethoscope system and design of an optimum filter based on tissue sound transmission for noninvasive early diagnosis of malfunction of an implanted mechanical total artificial heart.
Okamoto E, Inoue T, Hashimoto T, Saito I, Abe Y, Chinzei T, Isoyama T, Imachi K, Mitamura Y. Okamoto E, et al. Artif Organs. 2004 Feb;28(2):226-9. doi: 10.1111/j.1525-1594.2004.47226.x. Artif Organs. 2004. PMID: 14961963
The optimum frequency characteristics of a low-pass filter for the elimination of ambient sound through the electro-stethoscope casing were obtained by simulating sound transmission through tissue. We evaluated the usefulness of the electro-stethoscope system using a go
The optimum frequency characteristics of a low-pass filter for the elimination of ambient sound through the electro-stethoscope casing